Extracted standards
26 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Other
- Align access points across street
Vehicular ingress and egress shall align with access points located across the street, whenever possible.
- Building entrance features
Large commercial buildings shall have clearly defined, highly visible customer entrances featuring no less than three of the following: canopies, overhangs, recesses, arcades, raised corniced parapets, peaked roof forms, arches, outdoor patios, display windows, architectural detail, or integral planters.
- Building massing articulation
Large commercial buildings shall incorporate two or more design elements on each façade visible from a street: changes in wall plane, distinct changes in texture/color, variations in roof form, glazing of 40% of at least two elevations, vertical accents, or side walls exceeding 30 ft with articulation.
- Curbside pickup compliance
Commercial uses that include curbside pickup shall comply with the standards in Sec. 40.2-301(E)(7) Curbside Pickup Area Parking Requirements.
- Drive-through compliance
Commercial uses that include a drive-through shall comply with the standards in Sec. 40.2-302 Vehicular Stacking, Circulation, and Loading.
- Valet parking compliance
Commercial uses that include valet parking shall comply with the standards in Sec. 40.2-301(F)(5) Valet Parking.
- Internal street network connection
The internal network of streets shall connect to adjacent existing streets to better integrate the development with its context.
- Consistent façade articulation
Outbuildings within the same development shall include a consistent level of façade articulation on façades facing public streets, a gathering space, or parking lots.
- Consolidate driveways
Driveways shall be consolidated in order to reduce curb cuts, where possible.
- Coordinate with transit facilities
Site design, including entrances and parking lots, shall be coordinated with the location of existing and planned transit facilities.
- Corner lot glazing alternatives
On corner lots, other building façades that face a public street shall be designed with one or more of the following: glazing, recessed wall elements, mural, or alternative wall design approved by Zoning Administrator.
- Minimum glazing on front façade40 pct
the front façade of buildings shall provide glazing for at least 40 percent of the ground floor façade area between two feet above grade to eight feet above grade towards the street that the front façade faces.
- Outbuildings frame corners
Outbuildings shall frame the corner of an adjacent street intersection or entry point to the development.
- Parapet walls for flat roofs
When flat roofs are used, parapet walls with three dimensional cornice treatments shall be used to conceal roof-mounted equipment.
- Principal façade orientation
The principal façades shall face a public street serving the development to the greatest extent possible.
- Screen outdoor storage and loading
Outdoor storage, trash collection, and loading areas shall be integrated with the overall design of the building, or be screened in accordance with the standards in Sec. 40.2-304 Landscaping and Screening
- Screen rooftop equipment
All rooftop equipment shall be screened from all off-street views.
- Shopping cart storage secured
Exterior shopping cart storage areas shall be secured to the ground.
- Large commercial threshold60,000 sqftsq ftSquare feet. An acre is 43,560 sq ft; a typical suburban lot is 7,000–10,000.
all new buildings of 60,000 gross square feet in area or more shall comply with the following standards.
- Two most significant frontages
Where there are more than two public street frontages only the two more significant frontages in terms of traffic and exposure shall be required to meet the requirements for glazing or the above alternatives.
- Walkways along building façades
Be provided along the full length of building façades with an entryway or facing off-street parking areas.
- Pedestrian walkways connect buildings
Pedestrian walkways shall connect all buildings within a multi-building development with the public sidewalk.
- Minimum walkway width5 ft
Have a minimum width of five feet and comply with the Americans with Disabilities Act (ADA).
- Waste receptacle location
Large waste receptacles and refuse collection areas shall not be located within front or corner side yards.
Large waste receptacles and refuse collection areas and the fences or walls screening them shall maintain setbacks applicable for accessory buildings in the district where located.
- Waste receptacle surface
Areas intended for large waste receptacles and refuse collection shall be surfaced with concrete that meets or exceeds minimum city standards.
From the ordinance
Except as permitted in Sec. 33.1 of the City Code, no building or other permit shall be issued for a proposed commercial use unless such use is located on a lot that abuts a fully improved street.