Section 28-39(f)-(k)
Extracted standards
8 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Other
- Maximum uninterrupted facade length100 ft
In no case shall an uninterrupted facade length exceed one hundred (100) feet.
- Minimum number of entrance features3 count
Each commercial building shall have clearly defined, highly visible customer entrances featuring no less than three of the following...
- Minimum ground floor facade transparencyGround-floor transparencyThe share of a ground-floor street wall that must be windows rather than blank surface.60 pct
Ground floor facade that face a public street shall have arcades, display windows, entry areas, awnings, or other such features along no less than sixty (60) percent of their horizontal length.
- Minimum number of repeating pattern elements3 count
Facades must include a repeating pattern that shall include no less than three (3) of the following elements...
- Minimum number of roof features2 count
The primary building facade shall incorporate two (2) types of roof features or designs...
- Minimum depth of vertical elements as percentage of facade length3 pct
vertical elements such as wall plane projections or recesses having a depth of at least three (3) percent of the facade length
- Minimum extent of vertical elements as percentage of facade length20 pct
extending at least twenty (20) percent of the facade length
- Roof material quality
With the exception of flat roofs, all roof materials shall be durable, high-quality materials, comparable to standing seam metal or architectural grade dimensional asphalt shingles.
From the ordinance
Facades greater than one hundred (100) feet in length... shall incorporate vertical elements...