Surry, Virginia · General provision

Sec. 5-303

Extracted standards

5 individual requirements pulled out of this section’s prose, each with the sentence it came from.

Other

  • Accessible path width5 ft

    connected thereto by a paved surface with no less than five feet of unobstructed width

  • Disabled parking location

    Spaces for disabled parking shall be the closest to a building entrance for which they are provided

  • Maximum gradient for disabled parking path5 pct

    At no point shall the gradient exceed one foot rise or fall in 20 feet

  • Minimum length for disabled parking20 ft

    All spaces for disabled parking shall have minimum dimensions of 13 feet by 20 feet.

  • Minimum width for disabled parking13 ft

    All spaces for disabled parking shall have minimum dimensions of 13 feet by 20 feet.

From the ordinance

All spaces for disabled parking shall have minimum dimensions of 13 feet by 20 feet.
Sec. 5-303