Alexandria, Virginia · General provision

Sec. 2-145

Extracted standards

12 individual requirements pulled out of this section’s prose, each with the sentence it came from.

Other

  • Floor area multiplier for high ceilings2 x

    Floor area with a ceiling height 15 feet or greater shall be counted twice.

  • Floor area multiplier for very high ceilings3 x

    Floor area with a ceiling height 25 feet or greater shall be counted three times.

  • Architectural feature floor area exclusion30 in

    Architectural features up to a maximum projection of 30 inches extending beyond an exterior face of a building wall or column.

  • Attic floor area with a ceiling height of less than seven feet or where the space with the ceiling height of seven feet or more is less than four feet wide, as measured from the attic floor or floor joists if there is no floor, to the bottom of the roof rafters or underside of the roof deck if there are no rafters.

  • Attic floor area exclusion width4 ft

    Attic floor area with a ceiling height of less than seven feet or where the space with the ceiling height of seven feet or more is less than four feet wide, as measured from the attic floor or floor joists if there is no floor, to the bottom of the roof rafters or underside of the roof deck if there are no rafters.

  • Balcony floor area exclusion depth8 ft

    Space under open balconies and similar structures projecting from a floor above the first floor up to a maximum depth of eight feet.

  • Areas with a ceiling height of less than seven feet, except in an above grade parking garage constructed after March 17, 2018.

  • Any floor area that was used as a private or public garage prior to March 17, 2018 with a height of less than seven feet six inches.

  • Lavatories of which only a maximum of 50 square feet of each lavatory can be excluded. The maximum total of excludable area for lavatories shall be no greater than of ten percent of gross floor area.

  • Lavatory floor area exclusion percentage10 pct

    Lavatories of which only a maximum of 50 square feet of each lavatory can be excluded. The maximum total of excludable area for lavatories shall be no greater than of ten percent of gross floor area.

  • Loading spaces of which only a maximum of 850 square feet for each required loading space per section 8-200(B)(2) can be excluded.

  • Porch floor area exclusion depth8 ft

    Porticos and portions of porches, including wrap-around porches, up to eight feet in depth located on the first or ground floor without second-story enclosed construction above the portico or porch.

From the ordinance

Floor area with a ceiling height 15 feet or greater shall be counted twice. Floor area with a ceiling height 25 feet or greater shall be counted three times.
Sec. 2-145