Sec. 24-5503
Dimensional standards
Extracted standards
13 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Lighting
- Athletic event end time23 hour
Athletic events that are adjacent to existing residential development must be scheduled to end by 11 PM
- Maximum athletic field lighting heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first.95 ft
Lighting fixtures for outdoor sports areas, athletic fields, and performance areas must not exceed 95 feet in height
- Maximum bollard light heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first.4 ft
Any pedestrian bollard lamps must be mounted no higher than four feet above grade
- Full cut-off fixtures required
All exterior luminaries, including security lighting, must be full cut-off fixtures that are directed downward
- Hours of illumination
must extinguish all exterior lighting by within one hour of closing
- Light pole base requirement15 ft
In a parking lot or within 8 feet of the vehicular travel lane of a street or alley, any light pole over 15 feet in height must have a concrete base or equivalent structural support
- Maximum illumination at lot line
the maximum illumination measured in footcandles at ground level at any lot line does not exceed the standards in Table 5503B
- Maximum lighting heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. in industrial districts35 ft
In the A-1, M-1, M-2, and M-3 Districts more than 100 feet from all Residential Districts, 35 feet
- Maximum lighting heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. in other districts25 ft
In all other districts more than 100 feet from any Residential District, 25 feet
- Maximum lighting heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. in residential districts15 ft
In Residential Districts and within 100 feet of any Residential District, 15 feet
- Parking lot lighting required
Required lighting for off-street parking areas must be provided during hours of operation.
- Maximum pedestrian lighting heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first.15 ft
All fixtures for sidewalks, walkways, and trails outside of off-street parking lots must have a maximum height of 15 feet.
Light fixtures that imitate an official highway or traffic control light or sign or emergency vehicle lighting, or that have a flashing or intermittent pattern of illumination, are prohibited.
From the ordinance
All exterior luminaries, including security lighting, must be full cut-off fixtures that are directed downward