Sec. 24-5103
Extracted standards
8 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Other
- Minimum width for cemetery access20 ft
access must be provided by either a public right-of-way or a private accessway at least 20 feet in width extending from the cemetery or graveyard to a public street.
- Maximum fence heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. for cemetery separation42 in
The proposed development must be separated from the cemetery or graveyard by a fence between 36 and 42 inches in height
- Minimum fence heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. for cemetery separation36 in
The proposed development must be separated from the cemetery or graveyard by a fence between 36 and 42 inches in height
- Minimum residential setbackSetbackThe distance a building must be held back from a lot line. from cemetery20 ft
In the R-5A and R-5B Districts, the nearest residential lot must be at least 20 feet from the cemetery or graveyard.
- Maximum distance to mail facility1,400 ft
Shared mail delivery facilities must be located such that every dwelling or unit to be served by each facility is within 1,400 linear feet, as measured along the most direct pedestrian or vehicular way.
- Minimum width for pedestrian cross-access5 ft
Each required cross-access must consist of sidewalk at least 5 feet wide that is ADA accessible and lighted in accordance with Sec. 24-5504.C, Pedestrian Areas.
- Minimum illumination for shared facilities0.5 fc
For site features or facilities not listed in Section 24-5503, the average illumination must be at least 0.5 foot candles.
- Minimum width for vehicular cross-access22 ft
Each required cross-access must consist of a two-way driveway or drive aisle that is at least 22 feet wide or two one-way driveways or drive aisles that are each at least 14 feet wide.
From the ordinance
An internal vehicular circulation system in a nonresidential or mixed-use development... must be designed and constructed to provide vehicular cross-access... Each required cross-access must consist of a two-way driveway or drive aisle that is at least 22 feet wide or two one-way driveways or drive aisles that are each at least 14 feet wide.