Sec. 24-5313
Extracted standards
7 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Other
- Minimum heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. of tree protection barrier4 ft
A minimum four-foot-high wooden post and rail fence
- Minimum DBH for memorial/heritage/specimen tree22 in
Any healthy tree of a DBH of 22 inches or greater designated by the Board of Supervisors as a memorial, heritage, or specimen tree.
- Minimum DBH for protected tree in required yards6 in
Any healthy tree with a diameter at breast height (DBH) of six inches or greater located within any minimum required yard
- Replacement caliper inches per 1000 sq ftsq ftSquare feet. An acre is 43,560 sq ft; a typical suburban lot is 7,000–10,000. of woodland cleared4 caliper inches
One large deciduous or evergreen replacement tree, 4 caliper inches, for every 1,000 square feet of woodland cleared
- Replacement caliper inches per 10 inches DBH for unauthorized removal15 caliper inches
a minimum of 15 caliper inches of replacement trees must be planted for every ten inches DBH or fraction thereof of protected trees removed
- Replacement ratio for protected trees removed with permit1 trees
One replacement tree for each protected tree removed
- Tree protection zone extension beyond drip line1 ft
The tree protection zone of a protected tree consists of the area within the drip line of the tree extended one foot outward.
From the ordinance
Protected trees must not be removed unless a tree protection plan has been approved or a tree removal permit has been issued