Dimensional standards
Height & bulk
- Minimum landscaping
- 8%
Extracted standards
14 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Accessory structures
- AccessoryAccessory useA secondary activity customarily incidental to the main use of the lot — a garage, a home office. structure heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. less than principal building heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first.
The maximum height of any accessory structure shall be less than the height of the principal building.
- Cumulative accessoryAccessory useA secondary activity customarily incidental to the main use of the lot — a garage, a home office. structure footprint not exceed principal building footprint
The cumulative structure footprint of all accessory structures on the parcel shall not exceed the footprint of the principal building.
- Maximum accessoryAccessory useA secondary activity customarily incidental to the main use of the lot — a garage, a home office. structure footprint as percentage of principal building footprint75 pct
The footprint of any accessory structure shall not exceed seventy-five (75) percent of the building footprint of the principal building.
Other
- Maximum amateur radio tower heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first.75 ft
in no case shall they exceed a height of seventy-five (75) feet above ground level
- Maximum commercial turbine blade diameter30 ft
Horizontal axis turbines shall have a maximum blade diameter of thirty (30) feet.
- Maximum commercial wind turbine heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first.120 ft
The height of a freestanding turbine shall not exceed one hundred twenty (120) feet in overall height, including the blades.
- Maximum sign area per bollard for EV charging stations4 sqftsq ftSquare feet. An acre is 43,560 sq ft; a typical suburban lot is 7,000–10,000.
the maximum allowable sign area per bollard will be four (4) square feet
- Maximum roof-mounted commercial turbine heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. above roof60 ft
The overall height, including the blades, of a roof-mounted turbine shall not extend more than sixty (60) feet above the roof
- Maximum small wind turbine heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first. above roof20 ft
The height of the turbine, including blades, shall not extend more than twenty (20) feet above the roof
- Maximum small wind turbine blade diameter54 in
Horizontal axis turbines shall have a maximum blade diameter of fifty-four (54) inches.
- Maximum temporary family health care structure gross floor area300 sqftsq ftSquare feet. An acre is 43,560 sq ft; a typical suburban lot is 7,000–10,000.
The structure shall not exceed three hundred (300) square feet in gross floor area
- Minimum dumpster setbackSetbackThe distance a building must be held back from a lot line. from residentially zoned lot15 ft
such containers shall be located no closer than fifteen (15) feet to the abutting residentially zoned lot
- Minimum lot areaMinimum lot areaThe smallest parcel on which the district allows anything to be built. per horse for private stables2 acresacre43,560 square feet — about the size of an American football field without the end zones.
Private stables, where permitted by this chapter, shall require a minimum lot area of two (2) acres for each horse in the stable.
- Solar energy system landscaping strip width8 ft
Solar energy systems shall provide and maintain an 8' wide landscaping strip
From the ordinance
The footprint of any accessory structure shall not exceed seventy-five (75) percent of the building footprint of the principal building.