Municipality · Virginia

Portsmouth

This locality is on the roster but its ordinance has not been retrieved yet.
0
Districts
307
Extracted rules
1,326
Standards
6
Chapters read
Zoning snapshotNot yet acquired

General provisions

307 rules that bind every district rather than one — sign regulations, parking, floodplain and the rest of the code’s citywide chapters.

Sec. 40.2-217(G)(8)(b)6 standards

A car wash shall utilize a low-volume water recycling system, which provides for an average of at least 80 percent recycled water per wash. No water produced by activities at the facility shall be permitted to fall upon or drain across public streets, sidewalks, or adjacent properties. Vehicle stacking spaces shall comply with the standards in Sec. 40.2-302(A). A car wash and all associated uses must comply City Code Sec. 24-255 Unlawful Excessive Sound. If a car wash or auto detailing use abuts a residentially zoned property, all associated buildings must be set back a minimum of 25 feet from the abutting residential lot line. All car wash and auto detailing uses shall comply with the city and state's stormwater regulations.

Sec. 40.2-217(G)(8)(c)1 standards

Minor repair and storage of all vehicles shall occur within an enclosed building.

Sec. 40.2-217(G)(8)(d)3 standards

Opaque fencing and/or landscaping at least six feet and no greater than eight feet in height shall be in installed along the entire length of properties abutting any residential zoning districts.

Sec. 40.2-217(H)(1)(a)2 standards

Be within an enclosed building. Use nonflammable liquids in the cleaning processes that emit no odor, fumes, or steam detectable to normal senses from off the premises.

Sec. 40.2-217(H)(1)(b)6 standards

The minimum lot area shall be at least two acres. In a single-level self-service storage facility, interior parking shall be provided in the form of aisle ways adjacent to the storage bays. The minimum width of these aisle ways shall be 21 feet if only one-way traffic is permitted, and 30 feet if two-way traffic is permitted.

Sec. 40.2-217(H)(1)(b)8 standards

The minimum lot area shall be at least two acres.

Sec. 40.2-217(H)(1)(c)3 standards

Flammable liquids or gases in excess of 1,000 gallons shall be stored underground.

Sec. 40.2-217(H)(1)(d)3 standards

Containers used for fuel oil storage shall not exceed an individual capacity of 275 gallons.

Sec. 40.2-217(H)(2)(a)2 standards

Temporary outdoor storage may be allowed in an outdoor storage area that is no larger than 25 percent of the buildable area of the lot.

Sec. 40.2-217(H)(2)(b)4 standards

Storage of gaseous materials shall be limited to quantities not exceeding 500,000 cubic feet and not located within 100 feet from any lot line.

Sec. 40.2-217(H)(3)(a)1 standards

Drive aisles at least 50 feet wide shall be provided between rows of shipping containers.

Sec. 40.2-217(H)(3)(b)6 standards

The minimum lot size for a shipping container/chassis storage yard shall be two (2) acres.

Sec. 40.2-217(H)(4)(a)6 standards

The minimum area of a parcel proposed for development as a CDD Landfill must be 20 acres. No disposal unit (disposal cell) or leachate storage unit shall be located within fifty feet of the lot line on which the landfill is located; or two hundred feet of a lot line of any educational facility, health care facility or religious institution.

Sec. 40.2-217(H)(4)(a)6 standards

The minimum area of a parcel proposed for development as a CDD Landfill must be 20 acres.

Sec. 40.2-217(H)(4)(b)3 standards

The use shall be screened with a solid fence that is at least eight feet high in accordance with Sec. 40.2-304(F) Screening.

Sec. 40.2-217(H)(4)(c)4 standards

The center shall be on a parcel with an area of at least five acres.

Sec. 40.2-217(H)(4)(d)2 standards

Four off-street parking spaces shall be provided adjacent to the collection area.

Sec. 40.2-217(H)(4)(e)3 standards

The facility shall be located on a parcel with an area of at least three acres.

Sec. 40.2-217(H)(f)3 standards

Solar energy equipment (excluding solar panels or collectors) may project into side and rear setbacks no closer than two feet from any lot line.

Sec. 40.2-217(H)(g)7 standards

The minimum area of a parcel proposed for development as a transfer station is four acres.

Source documents