Sec. 7-9-108
Dimensional standards
Lot
Height & bulk
Servicing
- Geographic extent
- Only in non-urbanized areas as defined by Government Code Section 65944(d)(2)
Extracted standards
10 individual requirements pulled out of this section’s prose, each with the sentence it came from.
Other
- Minimum distance between ground and turbine blade15 ft
The minimum distance between the ground and any part of the turbine blade shall be fifteen (15) feet.
- No climbing apparatus within first 12 feet12 ft
Tower structure shall not have any climbing apparatus within the first twelve (12) feet from the ground.
- Landscaping to screen accessoryAccessory useA secondary activity customarily incidental to the main use of the lot — a garage, a home office. structures
Landscaping shall be provided to screen accessory structures from roads and adjacent residences in compliance with section 7-9-71.
- Lighting prohibitedProhibitedNot allowed in the district at all, short of rezoning or a variance. unless required by FAA, FCC, or building code
Tower structure lighting shall be prohibited unless required by the FAA, FCC or building code.
- Maximum tower heightMaximum heightThe tallest a building may be, given in feet, in storeys, or both — whichever binds first.80 ft
Maximum tower height shall be eighty (80) feet unless applicant can demonstrate special circumstances that require a tower up to one hundred (100) feet.
- Comply with Noise Control regulations
The applicant shall demonstrate that the system shall be operated in such a manner as to comply with the requirements set forth in Title 4, Division 6 of the Codified Ordinances of the County of Orange, entitled 'Noise Control.'
- Removal if inoperable for more than 12 months12 months
System shall be removed if inoperable for more than twelve (12) consecutive months.
- SetbackSetbackThe distance a building must be held back from a lot line. from property line
Minimum setback for the system shall be at least two (2) times the height of the system from any property line. No part of the system, including guy wire anchors, shall extend closer than thirty (30) feet from any property line.
- Sign restrictions
No sign shall be attached to the system, except for signs that identify the manufacturer, installer, or owner of the system; or public health and safety signs. Signs shall be no larger than four (4) square feet.
- Minimum distance between towers
Minimum distance between towers shall be at least one and one-half (1.5) times the height of the taller tower.
From the ordinance
Minimum lot size shall be one (1) acre. Maximum tower height shall be eighty (80) feet. Setback at least two times height from property line. No part closer than 30 feet.