County (unincorporated) · California

Riverside County Unincorporated

This locality is on the roster but its ordinance has not been retrieved yet.
61
Districts
449
Extracted rules
1,534
Standards
72
Chapters read
Zoning snapshotNot yet acquired

Zoning districts

61 districts, grouped by category.

Residential

36
PA-15Residential

Planning Area 15

Riverside County Unincorporated, CA
PA-17Residential

Planning Area 17 of Specific Plan No. 342

Riverside County Unincorporated, CA
Min lot
2,800 sq ft
Max height
55 ft
Front setback
10 ft
Permitted uses
17
PA-19Residential

Planning Area 19

Riverside County Unincorporated, CA
PA-20Residential

Planning Area 20 of Specific Plan No. 342

Riverside County Unincorporated, CA
Min lot
2,800 sq ft
Max height
55 ft
Front setback
10 ft
Permitted uses
28
PA-24Residential

Planning Area 24, Specific Plan No. 260

Riverside County Unincorporated, CA
Min lot
5,000 sq ft
Front setback
12 ft
PA-25Residential

Planning Area 25, Specific Plan No. 260

Riverside County Unincorporated, CA
Min lot
3,500 sq ft
Front setback
12 ft
PA-28Residential

Planning Area 28 - Attached Multiple Family Residential and Combined Multiple Family Residential/Non-Residential Development

Riverside County Unincorporated, CA
Min lot
2,800 sq ft
Max height
55 ft
Front setback
10 ft
PA-31Residential

Planning Area 31

Riverside County Unincorporated, CA
Min lot
5,000 sq ft
Front setback
15 ft
PA-32Residential

Planning Areas 32 and 33B

Riverside County Unincorporated, CA
Min lot
5,000 sq ft
Front setback
15 ft
PA-33AResidential

Planning Area 33A

Riverside County Unincorporated, CA
Min lot
6,000 sq ft
Front setback
12 ft
PA-34Residential

Planning Area 34

Riverside County Unincorporated, CA
Min lot
5,000 sq ft
Front setback
12 ft
PA-35Residential

Planning Areas 35, 37 and 40

Riverside County Unincorporated, CA
Min lot
6,000 sq ft
Front setback
12 ft
PA-36Residential

Planning Area 36, Specific Plan No. 260

Riverside County Unincorporated, CA
Min lot
10,000 sq ft
PA-38Residential

Planning Area 38

Riverside County Unincorporated, CA
Min lot
6,000 sq ft
Front setback
12 ft
PA-39Residential

Planning Area 39

Riverside County Unincorporated, CA
Min lot
5,000 sq ft
Front setback
12 ft
Permitted uses
1
PA-41Residential

Planning Areas 41, 42, 45 and 46

Riverside County Unincorporated, CA
Min lot
5,000 sq ft
Front setback
12 ft
PA-50CResidential

Planning Area 50C

Riverside County Unincorporated, CA
Min lot
4,500 sq ft
Max height
35 ft
Front setback
15 ft
Permitted uses
3
PA-52Residential

Planning Area 52

Riverside County Unincorporated, CA
Max height
35 ft
Front setback
15 ft
Permitted uses
3
PA-52AResidential

Planning Area 52A

Riverside County Unincorporated, CA
Min lot
6,000 sq ft
Max height
35 ft
Front setback
15 ft
Permitted uses
2
PA-58Residential

Planning Area 58

Riverside County Unincorporated, CA
Min lot
4,000 sq ft
Max height
35 ft
Front setback
15 ft
Permitted uses
1
R-1Residential

R-1 One-Family Dwelling Zone

Riverside County Unincorporated, CA
Min lot
7,200 sq ft
Max height
40 ft
Permitted uses
18
R-1Residential

One-Family Dwelling Zone

Riverside County Unincorporated, CA
Max height
35 ft
R-1AResidential

R-1A One-Family Dwellings, Mountain Resort Zone

Riverside County Unincorporated, CA
Min lot
7,200 sq ft
Max height
40 ft
Front setback
20 ft
Permitted uses
16
R-1AResidential
Riverside County Unincorporated, CA
Front setback
20 ft
R-2Residential

Multiple-Family Dwelling Zone

Riverside County Unincorporated, CA
Min lot
7,200 sq ft
Max height
40 ft
Front setback
20 ft
Permitted uses
34
R-2Residential

Multiple-Family Dwelling Zone

Riverside County Unincorporated, CA
Max height
35 ft
R-2AResidential

R-2A LIMITED MULTIPLE-FAMILY DWELLING ZONE

Riverside County Unincorporated, CA
Min lot
7,200 sq ft
Max height
30 ft
Permitted uses
19
R-3Residential

General Residential Zone

Riverside County Unincorporated, CA
Min lot
7,200 sq ft
Max height
50 ft
Front setback
10 ft
Permitted uses
25
R-3AResidential

Village Tourist Residential Zone

Riverside County Unincorporated, CA
Min lot
9,000 sq ft
Max density
20 du/ac
Permitted uses
39
R-4Residential

Planned Residential Zone

Riverside County Unincorporated, CA
Min lot
3,500 sq ft
Max height
50 ft
Front setback
20 ft
Max density
7.26 du/ac
Permitted uses
9
R-5Residential

R-5 Open Area Combining Zone, Residential Developments

Riverside County Unincorporated, CA
Max height
50 ft
Front setback
50 ft
Permitted uses
9
R-6Residential

R-6 Residential Incentive Zone

Riverside County Unincorporated, CA
Min lot
5,000 sq ft
Max height
35 ft
Front setback
10 ft
Max density
4 du/ac
Permitted uses
2
R-7Residential

R-7 Zone Highest Density Residential

Riverside County Unincorporated, CA
Max height
75 ft
Front setback
0 ft
Permitted uses
17
SP-266Residential

Specific Plan No. 266, Planning Area 23b

Riverside County Unincorporated, CA
Front setback
5 ft
SP-342Residential

Specific Plan No. 342

Riverside County Unincorporated, CA
Min lot
2,000 sq ft
Max height
45 ft
Front setback
5 ft
Permitted uses
4
SP-386Residential

Specific Plan No. 386

Riverside County Unincorporated, CA
Min lot
4,500 sq ft
Max height
26 ft
Front setback
30 ft
Permitted uses
3

General provisions

388 rules that bind every district rather than one — sign regulations, parking, floodplain and the rest of the code’s citywide chapters.

17.105.070 (2)12 standards

Lot area shall be not less than six thousand (6,000) square feet, unless cluster development subject to the development standards set forth in subsection AA. through GG. of this section is utilized. ... The minimum average width of that portion of a lot to be used as a building site shall be sixty (60) feet, with a minimum average depth of one hundred (100) feet ... The minimum frontage of a lot shall be sixty (60) feet ... Side yards on interior and through lots shall be not less than ten (10) percent of the width of the lot, but not less than three feet in width in any event, and need not exceed a width of five feet ... The rear yard shall not be less than ten (10) feet ... In no case shall more than sixty (60) percent of any lot be covered by buildings or structures.

17.105.0802 standards

The development standards for Planning Area A-4 of Specific Plan No. 303 shall be the same as those standards identified in Article XII, Section 12.4 of Ordinance No. 348, provided however that Article XII, Section 12.4(b)(3) shall apply only to setbacks calculated from public streets. Article XII, Section 12.4.a. is modified to provide that the minimum lot area shall be seven thousand (7,000) square feet with no minimum average width. There shall be no minimum setback from any private street. Article XII, Section 12.4c.(2) is modified to provide that an observation tower built within Planning Areas A-4 and built as part of a large scale recreational use shall not exceed seventy (70) feet in height and sports lighting, consisting of exterior nighttime lighting for ballfields, racetracks and other sporting activities, shall not be permitted.

17.105.080 (1), (2)2 standards

The uses permitted in Planning Area A-4 of Specific Plan 303 shall be the same as those uses permitted in Article XII, Section 12.2 of Ordinance No. 348, except that the uses permitted pursuant to Section 12.2.c. (3), (7), (11) and (12); Section 12.2.d.; Section 12.2.e., 12.2.f. and 12.2.g. shall not be permitted. In addition, the permitted uses identified under Section 12.2.b. shall include water wells and appurtenant facilities, facilities related to large scale recreational uses such as golf courses and a motor sports race track and facilities related thereto, including but not limited to race track, private garages, clubhouse, tuning shop, observation tower, museum, vehicle display areas, underground fuel storage and ancillary uses in support thereof; and when the gross acre of a lot is twenty (20) acres or greater, the uses identified under Article XIII, Section 13.1.a. and b. of Ordinance No. 348 shall also be included, except that the uses permitted pursuant to Section 13.1.a.(15) shall not be permitted. ... The development standards for Planning Area A-4 of Specific Plan No. 303 shall be the same as those standards identified in Article XII, Section 12.4 of Ordinance No. 348, provided however that Article XII, Section 12.4(b)(3) shall apply only to setbacks calculated from public streets. Article XII, Section 12.4.a. is modified to provide that the minimum lot area shall be seven thousand (7,000) square feet with no minimum average width. There shall be no minimum setback from any private street. Article XII, Section 12.4c.(2) is modified to provide that an observation tower built within Planning Areas A-4 and built as part of a large scale recreational use shall not exceed seventy (70) feet in height and sports lighting, consisting of exterior nighttime lighting for ballfields, racetracks and other sporting activities, shall not be permitted.

17.105.0902 standards

The development standards for Planning Areas A-6, E-2, and E-4 of Specific Plan No. 303 shall be the same as those standards identified in Article XII, Section 12.4 of Ordinance No. 348 except those development standards set forth in Article XII, a, b, c(2), and k shall be deleted and replaced by the following: a. Lot Size: Minimum lot area shall be seven thousand (7,000) square feet with no minimum average width. b. Standard Setbacks: 1. Where the front, side, or rear yard adjoins a street, the minimum setback shall be twenty-five (25) feet from any public street. 2. No minimum setback is required from any private street. 3. Front yard: No minimum. 4. Rear yard: No minimum. 5. Side yard: No minimum. c. Height Requirements: Buildings shall not exceed fifty (50) feet unless a height up to seventy-five (75) feet is approved pursuant to Article XVIII, Section 18.34. An observation tower built as part of large scale recreational use shall not exceed seventy (70) feet in height. d. Lighting: All lighting fixtures ... shall be focused, directed, and arranged to prevent glare or direct illumination on streets or adjoining property. Sports lighting ... shall not be permitted.

17.105.090 (1), (2)3 standards

The uses permitted in Planning Areas A-6, E-2 and E-4 of Specific Plan No. 303 shall be the same as those uses permitted in Article IX, Section 9.1a of Ordinance No. 348, except that the uses permitted pursuant to Article IX, Sections 9.1.a. (17), (23), (25), (27), (29), (32), (42), (51), (52), (61), (65), (67), (73), (83), (93) and (96-within Airport Land Use Compatibility Zone C); permitted under Sections 9.1.b. (7), (9), (10), (11.c), (13), (14), (15), (16), (18), (19), and (20); and permitted under Sections 9.1.d. (2), (4), (5), (9), (10), (12), (13), and (16) shall not be permitted; and uses permitted pursuant to Article IX, Section 9.1.a (35) shall not be permitted in Planning Areas E-2 and E-4. ... Minimum lot area shall be seven thousand (7,000) square feet with no minimum average width. ... Front yard: No minimum. Rear yard: No minimum. Side yard: No minimum. ... Buildings shall not exceed fifty (50) feet unless a height up to seventy-five (75) feet is approved pursuant to Article XVIII, Section 18.34.

17.105.100

The development standards for all uses in Planning Areas E-2A and E-2B of Specific Plan No. 303 except racetrack recreational units shall be the same as those standards identified in Article XII, Section 12.4 of Ordinance No. 348, except those development standards set forth in a., b., c.2., c.3., and k. shall be deleted and replaced by the following: a. Lot Size: Minimum lot area shall be seven thousand (7,000) square feet with no minimum average width. b. Standard Setbacks: 1. Where the front, side, or rear yard adjoins a public street, the minimum setback shall be twenty-five (25) feet from the property line. 2. No minimum setback is required from any private street. 3. Front yard: No minimum. 4. Rear yard: No minimum. 5. Side yard: No minimum. c. Height Requirements: Buildings shall not exceed fifty (50) feet unless a height up to seventy-five (75) feet is approved pursuant to Ordinance No. 348 Article XVIII,

17.105.100 (1), (2)

The uses permitted in Planning Areas E-2A and E-2B of Specific Plan No. 303 shall be the same as those uses permitted in Article IX, Section 9.1.a of Ordinance No. 348, except that the uses permitted pursuant to Article IX, Sections 9.1.a. (17), (23), (25), (27), (29), (32), (35), (42), (51), (52), (61), (65), (67), (72), (73), (83), (93) and (96); Sections 9.1.B. (7), (9), (10), (11.a,) (11.b), (11.c), (13), (14), (15), (16), (18), (19), and (20); Sections 9.1.D. (2), (4), (5), (9), (10), (11), (12), (13), and (16); and Sections 9.1.f.1.e. shall not be permitted. ... Minimum lot area shall be seven thousand (7,000) square feet with no minimum average width. ... Front yard: No minimum. Rear yard: No minimum. Side yard: No minimum. ... Buildings shall not exceed fifty (50) feet unless a height up to seventy-five (75) feet is approved pursuant to Ordinance No. 348 Article XVIII

17.105.1102 standards

The development standards for Planning Area E-6 of Specific Plan No. 303 shall be the same as those standards identified in Article XII, Section 12.4 except those development standards set forth in Article XII, a, b, c(2), and k shall be deleted and replaced by the following: a. Lot Size: If residential uses are located contiguous to nonresidential uses, then the following standards shall apply: 1. Minimum lot area shall be seven thousand (7,000) square feet with no minimum average width. b. Standard Setbacks: 1. Where the front, side, or rear yard adjoins a street, the minimum setback shall be twenty-five (25) feet from any public street. 2. No minimum setback is required from any private street. 3. Front yard: No minimum. 4. Rear yard: No minimum. 5. Side yard: No minimum. c. Building Height: Buildings shall not exceed fifty (50) feet unless a height up to seventy-five (75) feet is approved pursuant to Article XVIII, Section 18.34. An observation tower built within as part of large scale recreational use shall not exceed seventy (70) feet in height. d. Lighting: All lighting fixtures ... shall be focused, directed, and arranged to prevent glare or direct illumination on streets or adjoining property. Sports lighting ... shall not be permitted.

17.105.110 (1)

The uses permitted in Planning Area E-6 of Specific Plan No. 303 shall be the same as those uses permitted in Article IX, Section 9.1 of Ordinance No. 348, except that the uses permitted pursuant to Article IX, Sections 9.1.a. (17), (23), (25), (27), (29), (32), (42), (51), (52), (61), (65), (67), (73), (83), and (93); allowed under Sections 9.1.b. (7), (9), (10), (11.c), (13), (14), (15), (16), (18), (19), and (20); and allowed under Sections 9.1.d. (2), (4), (5), (9), (10), (12), (13), and (16) shall not be permitted.

17.105.120

The uses permitted in Planning Areas E-5, E-7 and E-8 of Specific Plan No. 303 shall be the same as those uses permitted in Article IX, Section 9.1 of Ordinance No. 348, except that the uses permitted pursuant to Article IX, Sections 9.1.a. (17), (23), (25), (27), (29), (32), (35), (42), (51), (52), (61), (65), (67), (73), (83), (93), and (96); Sections 9.1.b. (7), (9), (10), (11.a), (11.b), (11.c), (13), (14), (15), (16), (18), (19), and (20); and Sections 9.1.d. (2), (4), (5), (9), (10), (12), (13), and (16) shall not be permitted.

17.105.1202 standards

Minimum lot area shall be seven thousand (7,000) square feet with no minimum average width. Buildings shall not exceed fifty (50) feet unless a height up to seventy-five (75) feet is approved.

17.105.120 (2)3 standards

Minimum lot area shall be seven thousand (7,000) square feet with no minimum average width. ... Front yard: No minimum. Rear yard: No minimum. Side yard: No minimum. ... Buildings shall not exceed fifty (50) feet unless a height up to seventy-five (75) feet is approved pursuant to Article XVIII, Section 18.34.

17.105.130 (1)

The uses permitted in Planning Area M-4 of Specific Plan No. 303 shall be the same as those uses permitted in Article VI, Section 6.1 of Ordinance No. 348. In addition, the permitted uses identified under Section 6.1.a. shall include government offices, courthouses, police stations, fire stations, libraries, museums, and public schools.

17.106.0103 standards

The minimum front and rear yard setbacks shall be ten (10) feet. ... No lot shall have more than eighty (80) percent of its net area covered with buildings or structures. All buildings and structures shall not exceed eighty (80) feet in height.

17.106.0203 standards

The minimum lot area for the individual lots used as a residential building site shall be two thousand (2,000) square feet. ... Residential lots shall provide a minimum yard setback of fifteen (15) feet for front yards, five feet for side yards and ten (10) feet for rear yards and street-side side yards.

17.106.030

No minimum lot size. No minimum yard depths.

17.107.01013 standards

There is no minimum lot area. ... All buildings and structures shall not exceed seventy (70) feet in height. In Zone C ... buildings shall be limited to no more than three stories.

17.107.02011 standards

All buildings and structures shall not exceed thirty-five (35) feet in height. Lot area shall be no less than two thousand (2,000) square feet. ... In no case shall more than seventy (70) percent of any lot be covered by buildings.

17.107.0306 standards

The minimum setback from an arterial (Varner Road) shall be ten (10) feet. ... structures and buildings shall not exceed sixty (60) feet. In Zone C ... buildings shall be limited to no more than three stories.

17.107.0405 standards

The minimum setback from an arterial (Varner Road) shall be twenty (20) feet. ... No building or structure shall exceed seventy (70) feet in height. In Zone C ... buildings shall be limited to no more than three stories.